SolarEdge Isolation fault (PV array not isolated from ground). What it means, the usual causes, and what is safe to check.
SolarEdge Isolation fault (PV array not isolated from ground): What It Means and What to Do
Every time the inverter wakes up it checks that the DC wiring is not leaking current to ground.
What it means
Every time the inverter wakes up it checks that the DC wiring is not leaking current to ground. If the measured resistance to ground is below SolarEdge's limit, the inverter refuses to run and reports an isolation fault. It is a safety shutdown, and it usually points to a wiring, module or optimizer problem somewhere on the roof.
Code: Error 18x86 (SetApp) / 2x19 (inverter LCD), single phase; 8x58 on three phase
Common causes
- A module, optimizer or DC connector with damaged or wet insulation
- Unshielded or pinched DC wiring touching metal, such as racking or conduit
- Moisture in a connector or junction box after heavy rain, which is common in Florida summers and storms
- A failed optimizer or, less often, an internal inverter fault
- Roof leaks or storm damage that let water reach wiring
Safe checks you can do
- Look at the inverter display or the SolarEdge app to confirm the exact code, then take a photo of it
- Check whether it clears on its own after the roof and wiring dry out, and note whether it only happens after rain
- Do not open the inverter, touch roof wiring or try to switch DC connectors yourself
- When to call a technician
Call a licensed solar technician as soon as the code shows up, because the system is not producing and finding the leaking string needs a certified technician with test gear. Call right away if you see water near the inverter or wiring, scorch marks, or smell burning. Call 866-412-4218 or book online.
Installer out of business?
You can still get this fixed. SolarEdge backs its own equipment warranty, separate from the company that installed it, and a licensed Florida contractor can diagnose the fault and file the claim. Check whether your installer is still in business.
Source
Explained in our own words from SolarEdge documentation. AllSolar Energy is not affiliated with SolarEdge. Never open an inverter or touch roof wiring yourself.
Questions
What does SolarEdge Error 18x86 (SetApp) / 2x19 (inverter LCD), single phase; 8x58 on three phase mean?
Every time the inverter wakes up it checks that the DC wiring is not leaking current to ground. If the measured resistance to ground is below SolarEdge's limit, the inverter refuses to run and reports an isolation fault. It is a safety shutdown, and it usually points to a wiring, module or optimizer problem somewhere on the roof.
Can I fix it myself?
Look at the inverter display or the SolarEdge app to confirm the exact code, then take a photo of it Check whether it clears on its own after the roof and wiring dry out, and note whether it only happens after rain Do not open the inverter, touch roof wiring or try to switch DC connectors yourself Do not open the inverter or touch DC wiring.
My installer closed. Who fixes a SolarEdge Error 18x86 (SetApp) / 2x19 (inverter LCD), single phase; 8x58 on three phase?
Any licensed Florida solar or electrical contractor. SolarEdge equipment warranties usually survive the installer, and the contractor can file the claim.